| Leonid Ganeline 2006-02-01, 5:56 pm |
| There are some odds in setting up the Service Window for ports...
1. Receive locations have the whole set of parameters: "Start Date", "Stop
Date", "Enable the Service Window", "Start Time", "Stop Time".
Send ports have only "Enable the Service Window", "Start Time", "Stop Time"
and don't have "Start Date", "Stop Date".
Why?
My idea is because the Send ports should always clean up the message box.
It's quite unlikely to get the situation when the BizTalk receives the
messages but could not send them because the Service Window on the Send
ports are disabled. It's the way to overload the system.
In another words: "It is possible to disable the send ports several hours,
but not several days". It's only my assumption.
2. When we create a Binding file by the BizTalk Deployment Wizard,
parameters of the Service Window are saved for Send ports but not for the
Receive ports (locations).
Why?
My idea is because these parameters an operator can change in the production
environment with the BizTalk Administration Console. And have to set them
only with the BizTalk Administration Console.
If you have any ideas about subj, please, give a feedback
Thanks,
http://geekswithblogs.net/leonidganeline
Leonid Ganeline
BizTalk Developer
|