Data Storage - LPFC and Powepath Errors

This is Interesting: Free IT Magazines  
Home > Archive > Data Storage > October 2007 > LPFC and Powepath Errors





You are viewing an archived Text-only version of the thread. To view this thread in it's original format and/or if you want to reply to this thread please [click here]

Author LPFC and Powepath Errors
Doknik

2007-10-15, 1:14 pm



All,

I am seeing these errors after a series of upgrades on our work
machine.After completing these software, firmware and driver upgrades and
rebooting i encountered the following errors.

We updated Veritas vxvm to version 4.1 , EMC powerpath to version 5.1 ,LPFC
firmware for emulux cards from 3.90a7 to 3.93.,gethbainfo ,HBAnyware

Upon reboot the machine complained of the following errors and now a format
command only shows the 2 internal disks only but not the EMC san disks

commands such as
powermt display.......... returns nothing
powercf check.......... says something along the lines of......no valid
config files found
powermt display dev=all shows nothing and sometimes it says Device(s) not
found

All storage gurus please come to our rescue
EMC cant help, Sun also says its an EMC problem ......we are stuck in the
middle


This a snipppet of the errors during a reboot.O

Can't find clone devinfo node
WARNING: lpfc0: Attach failure: Unable to create LAN node
WARNING: Cannot create minor node for <pci10df,f900> <lpfc> <1>
Can't find clone devinfo node
WARNING: lpfc1: Attach failure: Unable to create LAN
WARNING: forceload of drv/pci failed
WARNING: forceload of drv/emcp failed
WARNING: forceload of drv/scsi failed
WARNING: forceload of misc/emcpmpc failed
WARNING: forceload of misc/emcppn failed
WARNING: forceload of misc/emcpioc failed
WARNING: forceload of misc/md_trans failed
WARNING: forceload of misc/md_raid failed
WARNING: forceload of misc/md_hotspares failed
WARNING: forceload of misc/md_sp failed
Hardware watchdog enabled
Initialization error.
VxVM sysboot INFO V-5-2-3390 Starting restore daemon...
VxVM sysboot INFO V-5-2-3409 starting in boot mode...
Oct 13 20:42:08 vxvm:vxconfigd: V-5-1-8645 Error in claiming
/dev/rdsk/emcpower2c by NR list: I/O error
Oct 13 20:42:08 vxvm:vxconfigd: V-5-1-8645 Error in claiming
/dev/rdsk/emcpower0c by NR list: I/O error
Oct 13 20:42:08 vxvm:vxconfigd: V-5-1-8645 Error in claiming
/dev/rdsk/emcpower1c by NR list: I/O error
NOTICE: VxVM vxdmp V-5-0-34 added disk array DISKS, datype = Disk


EMC support think we have all the right configurations for our SAN to work
..We sent them output for emcgrab.sh

Help please anyone.

Your help would be greatly appreciated

Thanks