| Kris Seraphine 2006-11-28, 1:11 am |
| I figured it out....
The pair needed to be straight-through on the cable.
On 11/27/06, Kris Seraphine <baryonyx5@gmail.com> wrote:
>
> Hi
>
> I'm testing a customer's analog lines in preparation for migrating them
> off of their key system onto the corporate CCM system. They have 4 analog
> DID trunks that work fine on the key system. I have a 2821 gateway with a
> VIC2-4FXS/DID card. When I connect the DID trunks to the FXS/DID port and
> place an incoming call to a DID I immediately get fast busy. I believe the
> signaling to be wink-start but I've tried setting the ports to immediate and
> delay with no success. Here's the configuration for one of the ports.
>
> voice-port 0/2/0
> signal did immediate
>
> What seems odd to me is that when I debug vpm signal and vtsp all I don't
> see anything when I place the call. There's no debug output and the port is
> never activated (the green light does not come on). I'm trying to get in
> touch with the telco but I thought I'd ask here in the mean time.
>
>
> I know the card is good (at least it works fine when configured as a
> station port card). Is there anything else I'm missing?
>
> --
> kris seraphine
--
kris seraphine
|