Home > Archive > Voice Over IP in UK > September 2006 > Draytek 2800 and Sipgate/voiptalk -- what are the settings?
You are viewing an archived Text-only version of the thread.
To view this thread in it's original format and/or if you want to reply to
this thread please [click here]
| Author |
Draytek 2800 and Sipgate/voiptalk -- what are the settings?
|
|
|
| I'm trying to set up my new Draytek 2800 VG with my Sipgate and
voiptalk accounts
However, whichever way I try, I can't seem to get either to register
in the SIP account list.
The Sipgate web page should have some help for the 2600, but I cannot
see it
Voiptalk have instructions for the 2600, which are slightly different
and, even f I adapt them, they don't work
Can someone take me by hand and point out what I have overlooked?
The current (non working setup) is
Stun server (empty)
Sipgate
Register via WAN
SIP port 5060
Domain/Realm sipgate.co.uk
Proxy sipgate.co.uk
Act as outbound proxy (enabled)
Display name ABC
Account number name, the name I registered with sipgate
Authentication ID checked 1234567 (my own)
Password, (the SIP password from my account on the sipgate page)
NAT traversal support None
Then in phone settings, I have DTMF mode set to SIP INFO (cisco)
Dialplan is empty
Thanks
Lorenz
[L.]
| |
| {{{{{Welcome}}}}} 2006-09-08, 7:11 pm |
| Thus spaketh [L.]:
> I'm trying to set up my new Draytek 2800 VG with my Sipgate and
> voiptalk accounts
>
> However, whichever way I try, I can't seem to get either to register
> in the SIP account list.
>
> The Sipgate web page should have some help for the 2600, but I cannot
> see it
> Voiptalk have instructions for the 2600, which are slightly different
> and, even f I adapt them, they don't work
>
> Can someone take me by hand and point out what I have overlooked?
>
> The current (non working setup) is
>
> Stun server (empty)
>
> Sipgate
>
> Register via WAN
> SIP port 5060
> Domain/Realm sipgate.co.uk
> Proxy sipgate.co.uk
> Act as outbound proxy (enabled)
> Display name ABC
> Account number name, the name I registered with sipgate
> Authentication ID checked 1234567 (my own)
Should not both Account number name & Authentication ID be your Sipgate
SIP ID.
> Password, (the SIP password from my account on the sipgate page)
> NAT traversal support None
>
> Then in phone settings, I have DTMF mode set to SIP INFO (cisco)
>
> Dialplan is empty
>
> Thanks
>
> Lorenz
>
> [L.]
| |
|
| On Fri, 08 Sep 2006 18:33:40 GMT, "{{{{{Welcome}}}}}"
<bhx___spam@trapped___hotmail.co.uk> wrote:
>Thus spaketh [L.]:
[vbcol=seagreen]
>
>
>Should not both Account number name & Authentication ID be your Sipgate
>SIP ID.
Tried. No joy!
It must be something specific with Sipgate, because voiptalk has
started working, with the same settings.
Lorenz
[L.]
| |
| John Geddes 2006-09-11, 7:11 am |
| [L.] wrote:
> I'm trying to set up my new Draytek 2800 VG with my Sipgate and
> voiptalk accounts
For what it's worth, here are settings that work on my 2900VG with
Sipgate (albeit with less-than-brilliant sound quality)
SIP Port 5060
Domain sipgate.co.uk
Outbound Proxy [blank]
Register-Via: Auto
Display Name: WhateverYouLike
AccountName [Sipgate-ID from their page my_account.php]
Authentication ID Same as AccountName
Password [SIP-Password from same page - NOT the same as the
password you use to log in to your account on their website]
Expiry Time 1 Hour
Apart from Account Name, Authentication ID and Password, all details the
same for Port1 and Port2
Default Codec G.711A (64kbps)
Packet Size 20ms
Voice Active Detector Off
DTMF mode SIP Info
Dynamic RTP port start 5004
Dynamic RTP port end 5006
RTP TOS IP precedence 5
Dialtone Power Level 27
Ring Freq 25
NB - only one shortcoming: I also have a Sipura 2100 connected to the
LAN on the 2900, and whilst both Sipgate circuits on that unit can dial
in, out, and to each other, and both Sipgate circuits on the 2900's VOIP
ports can dial in, out, and to each other, calls from Drayek VOIP to
Sipura VOIP suffer one-way audio. Never got to the bottom of it. Does
anyone have suggestions?
John Geddes
Derbyshire
| |
|
| Top posting as I only want to say that John's settings below work
fine!
Lorenzo
On Mon, 11 Sep 2006 08:22:39 +0000, John Geddes
<john@st4rm4rkassociates.co.uk> wrote:
>[L.] wrote:
>
>For what it's worth, here are settings that work on my 2900VG with
>Sipgate (albeit with less-than-brilliant sound quality)
>
>SIP Port 5060
>Domain sipgate.co.uk
>Outbound Proxy [blank]
>Register-Via: Auto
>Display Name: WhateverYouLike
>AccountName [Sipgate-ID from their page my_account.php]
>Authentication ID Same as AccountName
>Password [SIP-Password from same page - NOT the same as the
>password you use to log in to your account on their website]
>Expiry Time 1 Hour
>
>Apart from Account Name, Authentication ID and Password, all details the
>same for Port1 and Port2
>
>
>Default Codec G.711A (64kbps)
>Packet Size 20ms
>Voice Active Detector Off
>
>DTMF mode SIP Info
>Dynamic RTP port start 5004
>Dynamic RTP port end 5006
>RTP TOS IP precedence 5
>
>Dialtone Power Level 27
>Ring Freq 25
[L.]
|
|
|
|
|