Problem with EDI X12 Envelope
Web Server forum
Back To The Forum Home!Search!Private Messaging System

Web Server Talk Web Server Talk > Web Servers reviews > BizTalk Server > BizTalk Server > Problem with EDI X12 Envelope




  Last Thread   Next Thread Next
  Show Printable Version Email this Page Subscribe to this Thread      Post New Thread    Post A Reply      

    Problem with EDI X12 Envelope  
Guess Nospam


View Ip Address Report This Message To A Moderator Edit/Delete Message


 
02-08-04 01:39 PM

I am having a problem generating a x12 997 functional acknowledgement using
a receipt channel in BizTalk2002.  I would really appreciate any insight
into how I might resolve the problem.  Below is a description of my problem:

I used the "EDI and Receipts" example from online help as a guide.  I don't
think I have missed any steps.

If I set my receipt port to no envelope I don't get an error.  If I use my
X12 envelope on my outgoing receipt port I get an error in the application
event log and the document sticks in the suspended queue.

The event log displays the following:
============
Event Type: Error
Event Source: BizTalk Server
Event Category: Document Processing
Event ID: 324
Date:  1/27/2004
Time:  12:12:10 PM
User:  N/A
Computer: RTPI
Description:
An error occurred in BizTalk Server.

Details:
------------------------------
[0x1807] The "EQS997" document is missing the entire property set that is
required for this serializer to run.

[0x0156] The server could not finish processing messaging port
"ReceiptPortToXYZ".

[0x1730] Suspended Queue ID: "{E8F4380C-32E2-4E65-8674-77B18B37B594}"

[0x180b] The serializer could not finish processing. See the following
messages for details.
============

If I use no envelope I get the following document:
<?xml version="1.0" encoding="UTF-16"?>
<X12_4010_997><AK1 AK101="IN" AK102="1"/><AK2Loop1><AK2 AK201="810"
AK202="0005"/><AK5 AK501="A" AK502="" AK503="" AK504="" AK505=""
AK506=""/></AK2Loop1><AK2Loop1><AK2 AK201="810" AK202="0004"/><AK5 AK501="A"
AK502="" AK503="" AK504="" AK505="" AK506=""/></AK2Loop1><AK2Loop1><AK2
AK201="810" AK202="0003"/><AK5 AK501="A" AK502="" AK503="" AK504="" AK505=""
AK506=""/></AK2Loop1><AK2Loop1><AK2 AK201="810" AK202="0002"/><AK5 AK501="A"
AK502="" AK503="" AK504="" AK505="" AK506=""/></AK2Loop1><AK9 AK901="A"
AK902="4" AK903="4" AK904="4" AK905="" AK906="" AK907="" AK908=""
AK909=""/></X12_4010_997>

Any assistance would be greatly appreciated.











[ Post a follow-up to this message ]



    Sponsored Links  




 





   All times are GMT. The time now is 08:55 AM.      Post New Thread    Post A Reply      
  Last Thread   Next Thread Next


Most Popular forums 

Forum Jump:
Rate This Thread:

Forum Rules:
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is OFF
vB code is ON
Smilies are ON
[IMG] code is OFF
 
Medical and Health forum | Computer Games Reviews | Graphics design forum

Back To The Top
Home | Usercp | Faq | Register