Envelop, EDI X12 850 to XML probelm
Web Server forum
Back To The Forum Home!Search!Private Messaging System

Web Server Talk Web Server Talk > Web Servers reviews > BizTalk Server > BizTalk Server General > Envelop, EDI X12 850 to XML probelm




  Last Thread   Next Thread Next
  Show Printable Version Email this Page Subscribe to this Thread      Post New Thread    Post A Reply      

    Envelop, EDI X12 850 to XML probelm  
Yogesh


View Ip Address Report This Message To A Moderator Edit/Delete Message


 
02-18-04 01:36 PM

I had used the envelop in receive function
in EDI X12 file processing gettig the following .
can any body tell me  how to this probelm. or is
nessasary provide the envelop,
If i not specifed the envelop in the receive function i
get the error descibed in Part-2

Part - 1)Event Type:	Error
Event Source:	BizTalk Server
Event Category:	Document Processing
Event ID:	324
Date:		2/19/2004
Time:		1:09:38 AM
User:		N/A
Computer:	DEVSERVER
Description:
An error occurred in BizTalk Server.

Details:
------------------------------
0xc00ce558
[0x1416] The specification failed to load. See the
following messages for details.

[0x1a20] The envelope "EDIEnvelop" could not be loaded.
A possible cause is that the specification is not valid.
Configure a valid envelope specification.

[0x1436] The envelope name "EDIEnvelop" does not
reference a valid envelope for the BizTalk Server parser.
Either the envelope name does not exist or there is an
envelope specification attached that is not valid.

[0x1416] The specification failed to load. See the
following messages for details.

[0x1730] Suspended Queue ID: "{4CD50EF6-9FEB-4FD3-B178-
630DD5B5E306}"

[0x1416] The specification failed to load. See the
following messages for details.


part-2)

Event Type:	Error
Event Source:	BizTalk Server
Event Category:	Document Processing
Event ID:	324
Date:		2/19/2004
Time:		1:08:38 AM
User:		N/A
Computer:	DEVSERVER
Description:
An error occurred in BizTalk Server.

Details:
------------------------------
[0x1439] No parser component recognizes the data. This
might be caused by an interchange specification that is
missing or not valid, or it might be caused by data that
is not valid. Verify that both the interchange
specification (if one is specified) and the data match.

[0x1730] Suspended Queue ID: "{68E211A8-2A7F-422A-A2E0-
1F73CE3F5CB9}"

[0x0147] The business document that was passed in is not
in a recognized format and could not be parsed or
decrypted.



please help as soon as possible
thank u

yogesh






[ Post a follow-up to this message ]



    Re: Envelop, EDI X12 850 to XML probelm  
Matt Cable


View Ip Address Report This Message To A Moderator Edit/Delete Message


 
02-25-04 06:35 PM

What are the properties of your "EDIEnvelop" in Message Manager?  Have you
picked X12 as the "Envelope format"?  If so a specification is not chosen.
The X12 engine (serializer and parser) handles the enveloping.

- Matt Cable

"Yogesh" <anonymous@discussions.microsoft.com> wrote in message
 news:12c4201c3f66a$c4198940$a601280a@phx
.gbl...
> I had used the envelop in receive function
> in EDI X12 file processing gettig the following .
> can any body tell me  how to this probelm. or is
> nessasary provide the envelop,
> If i not specifed the envelop in the receive function i
> get the error descibed in Part-2
>
> Part - 1)Event Type: Error
> Event Source: BizTalk Server
> Event Category: Document Processing
> Event ID: 324
> Date: 2/19/2004
> Time: 1:09:38 AM
> User: N/A
> Computer: DEVSERVER
> Description:
> An error occurred in BizTalk Server.
>
>  Details:
>  ------------------------------
>  0xc00ce558
>  [0x1416] The specification failed to load. See the
> following messages for details.
>
>  [0x1a20] The envelope "EDIEnvelop" could not be loaded.
> A possible cause is that the specification is not valid.
> Configure a valid envelope specification.
>
>  [0x1436] The envelope name "EDIEnvelop" does not
> reference a valid envelope for the BizTalk Server parser.
> Either the envelope name does not exist or there is an
> envelope specification attached that is not valid.
>
>  [0x1416] The specification failed to load. See the
> following messages for details.
>
>  [0x1730] Suspended Queue ID: "{4CD50EF6-9FEB-4FD3-B178-
> 630DD5B5E306}"
>
>  [0x1416] The specification failed to load. See the
> following messages for details.
>
>
>  part-2)
>
> Event Type: Error
> Event Source: BizTalk Server
> Event Category: Document Processing
> Event ID: 324
> Date: 2/19/2004
> Time: 1:08:38 AM
> User: N/A
> Computer: DEVSERVER
> Description:
> An error occurred in BizTalk Server.
>
>  Details:
>  ------------------------------
>  [0x1439] No parser component recognizes the data. This
> might be caused by an interchange specification that is
> missing or not valid, or it might be caused by data that
> is not valid. Verify that both the interchange
> specification (if one is specified) and the data match.
>
>  [0x1730] Suspended Queue ID: "{68E211A8-2A7F-422A-A2E0-
> 1F73CE3F5CB9}"
>
>  [0x0147] The business document that was passed in is not
> in a recognized format and could not be parsed or
> decrypted.
>
>
>
> please help as soon as possible
> thank u
>
> yogesh
>







[ Post a follow-up to this message ]



    Sponsored Links  




 





   All times are GMT. The time now is 03:19 PM.      Post New Thread    Post A Reply      
  Last Thread   Next Thread Next


Most Popular forums 

Forum Jump:
Rate This Thread:

Forum Rules:
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is OFF
vB code is ON
Smilies are ON
[IMG] code is OFF
 
Medical and Health forum | Computer Games Reviews | Graphics design forum

Back To The Top
Home | Usercp | Faq | Register