03-27-07 12:17 PM
Yes, and?
If you read the manual you'll see that using RAA with the UTE will by defaul
t disable all other portlet functionality. To enable it edit the server conf
iguration (tag Portal)and check the box for 'Enable base portlets for portal
..'
Recommendations: Update your UTE to at least 5.1.0.3 to escape a few bugs an
d quirks.
Gotchas: Wiring (and other configuration changes) done through the Test Envi
ronment using Rational will not persist. Just so you know. If you want it yo
u have to do it through the original interface.
Gotchas 2: When updating UTE to .3 you have to update it to .1 or .2 first (
both of which takes an eternity to update and are between 0.5 to 0.7 Gb to d
ownload). Update it manually (e.g. download it and then use the updater on t
he local directory)
Gotchas 3: There are (or was) a bug that didn't alter the version file for U
TE, so when updating from .1 (or .2) to .3 the updater will throw an error s
aying that the UTE is not updated enough to install the .3 fixpack. This is
easily remedied by altering
the text-file yourself. The file is PORTAL_UTE_HOME/wps.properties
Good luck.
/Jonas V
[ Post a follow-up to this message ]
|