07-23-04 10:45 PM
On 22 Jul 2004 11:31:14 -0700, jsaintjohn1@yahoo.com (J) wrote:
>Has anyone had an issues while in the process of creating new devices
>using the ECC software?
>We got about 90% of the way through the wizard (Logical Device
>Configuration) when the process failed during the commit phase.
>Suffice it to say this is not a good thing! Issues started occurring,
>and EMC was engaged.
Seen this on several occasions. Most common cause for the commit to
fail is a communication issue with the service processor or an
internal script failing for some reason. EMCs support people should be
able to clean that up in no time. From the error codes in the symapi
log and the state of the service processor they also should be able to
give you a good explanation what happened.
>ECC version = 5.1.2.1 (Windows 2000)
Check if Solution Enabler 5.4.2 is installed. If not I strongly
recommend an upgrade to this level with the DMX.
HTH
Frank