03-28-05 11:13 PM
Hi Nihit,
The problem seems to have gone away for now. For the longest time I could
reproduce it without a problem. The web.config contains the following:
<cache name="ShippingManagerCache" type="Shipping"
loaderProgId="Commerce.ShippingManagerCache" refreshInterval="0"
retryInterval="60" />
I'll be keeping an eye on it to see if it reoccurs. Something that did
happen around the same time it went away, however I'm not sure is related,
is that I added the SampleRegionalTaxCache to the web.config:
<cache name="SampleRegionalTaxCache" type="Tax"
loaderProgId="Commerce.SampleRegionalTaxCache" refreshInterval="0"
retryInterval="60" />
Cheers,
Colin
"Nihit Kaul [MSFT]" <nihitk@online.microsoft.com> wrote in message
news:FASTPf%23MFHA.964@TK2MSFTNGXA03.phx.gbl...
> So this does not occur when you run the Basket or the Checkout pipelines?
>
> With the ASP.Net based site, the cache etc. should be created and
> configured automatically according to the Web.Config settings.
>
> What are the web.config ShippingManagerCache settings like? Could you
> check
> the retry/refresh intervals set in the web.config file?
>
> Thanks,
>
> Nihit Kaul[MSFT]
> Commerce Server
> http://blogs.msdn.com/nihitk
>
> This posting is provided "AS IS" with no warranties, and confers no
> rights.
> Use of included script samples are subject to the terms specified at
> http://www.microsoft.com/info/cpyright.htm
> --------------------
> From: "Colin Bowern" <colin.bowern@nospam.officialcommunity.com>
> Subject: ShippingManagerCache Data Source Error
> Date: Mon, 14 Mar 2005 14:22:40 -0500
> Lines: 34
> X-Priority: 3
> X-MSMail-Priority: Normal
> X-Newsreader: Microsoft Outlook Express 6.00.2900.2527
> X-RFC2646: Format=Flowed; Original
> X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.2527
> Message-ID: <uh50ysMKFHA.3552@TK2MSFTNGP12.phx.gbl>
> Newsgroups: microsoft.public.commerceserver.general
> NNTP-Posting-Host: mail.officialcommunity.net 207.188.77.211
> Path:
> TK2MSFTNGXA02.phx.gbl!TK2MSFTNGXA01.phx.gbl!TK2MSFTNGP08.phx.gbl!TK2MSFTNG
P1
> 2.phx.gbl
> Xref: TK2MSFTNGXA02.phx.gbl microsoft.public.commerceserver.general:15760
> X-Tomcat-NG: microsoft.public.commerceserver.general
>
> Hi,
>
> In my total pipeline I'm running into a problem with the
> ShippingManagerCache. The CS2002 site is built on ASP.NET 1.1 and we've
> been using the starter site as a guide however not the class libraries
> included with them.
>
> When the total pipeline is first run it throws back the following error
> however after the retry interval it works fine:
>
> Event Type: Error
> Event Source: Commerce Server 2002
> Event Category: None
> Event ID: 8192
> Date: 3/14/2005
> Time: 2:02:05 PM
> User: N/A
> Computer: COLIN-DESKTOP
> Description:
> The CacheManager encountered an error during a refresh of the cache:
> 'Commerce.ShippingManagerCache: Could not connect to datasource'
>
> Any thoughts on what might be causing this? It seems to connect alright
> the
> second time. I've checked the connection strings in the Commerce Server
> Manager and they appear to be correct. Are we required to setup the
> CacheManager similar to what is outlined in the following for .NET apps?
>
> [url]http://msdn.microsoft.com/library/default.asp?url=/library/en-us/csvr2002/ht[/ur
l]
> m/cs_sp_shippingobj_vklo.asp
>
> Cheers,
> Colin
>
>
>
>
[ Post a follow-up to this message ]
|